{"id":10231,"date":"2023-05-31T09:23:32","date_gmt":"2023-05-31T09:23:32","guid":{"rendered":"https:\/\/imetrologie.com\/produkte\/uncategorized\/am1751\/"},"modified":"2024-08-14T10:39:52","modified_gmt":"2024-08-14T10:39:52","slug":"am1751","status":"publish","type":"product","link":"https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/","title":{"rendered":"AM1751"},"content":{"rendered":"<p>Manufacturer: AccuMac<\/p>\n<p>The AM1751 series of Secondary Reference PRTs offers affordable reference probes for precision temperature measurement and calibration both in the lab and in the field. These PRTs feature an accuracy of &lt;0.012\u00b0C and a short term stability of &lt;0.007\u00b0C.<\/p>\n<p>To reach the best performance in stability and repeatability, the sensing element has been specially designed to protect the platinum sensing wire from contamination at high temperatures. A unique supporting structure and filling material provide the best balance among the hysteresis effect, mechanical shock and thermal shock performance. This high performance probe fully meets the ITS-90 criteria for reference thermometers.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Secondary Reference PRT<\/p>\n","protected":false},"featured_media":7315,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[276],"product_tag":[339,340,334,329],"class_list":{"0":"post-10231","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-sprt-resistance-thermometer","7":"product_tag-attraktives-preis-leistungsverhaeltnis-en","8":"product_tag-genauigkeit-0-015k-bei-0-01c-en","9":"product_tag-kundenspezifische-abmessungen-sind-moeglich-en","10":"product_tag-temperaturbereich-200c-bis-670c-en","12":"first","13":"instock","14":"sold-individually","15":"shipping-taxable","16":"purchasable","17":"product-type-variable","18":"has-default-attributes"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SPRT AM1751 | imetrologie<\/title>\n<meta name=\"description\" content=\"Secondary reference SPRT from AccuMac in the temperature range from -200 \u00b0C to 670 \u00b0C. Inquire now!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SPRT AM1751 | imetrologie\" \/>\n<meta property=\"og:description\" content=\"Secondary reference SPRT from AccuMac in the temperature range from -200 \u00b0C to 670 \u00b0C. Inquire now!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/\" \/>\n<meta property=\"og:site_name\" content=\"Imetrologie\" \/>\n<meta property=\"article:modified_time\" content=\"2024-08-14T10:39:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/imetrologie.com\/wp-content\/uploads\/2023\/05\/AM1751_internet.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"666\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SPRT AM1751 | imetrologie","description":"Secondary reference SPRT from AccuMac in the temperature range from -200 \u00b0C to 670 \u00b0C. Inquire now!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/","og_locale":"en_US","og_type":"article","og_title":"SPRT AM1751 | imetrologie","og_description":"Secondary reference SPRT from AccuMac in the temperature range from -200 \u00b0C to 670 \u00b0C. Inquire now!","og_url":"https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/","og_site_name":"Imetrologie","article_modified_time":"2024-08-14T10:39:52+00:00","og_image":[{"width":1000,"height":666,"url":"https:\/\/imetrologie.com\/wp-content\/uploads\/2023\/05\/AM1751_internet.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/","url":"https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/","name":"SPRT AM1751 | imetrologie","isPartOf":{"@id":"https:\/\/imetrologie.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/#primaryimage"},"image":{"@id":"https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/#primaryimage"},"thumbnailUrl":"https:\/\/imetrologie.com\/wp-content\/uploads\/2023\/05\/AM1751_internet.png","datePublished":"2023-05-31T09:23:32+00:00","dateModified":"2024-08-14T10:39:52+00:00","description":"Secondary reference SPRT from AccuMac in the temperature range from -200 \u00b0C to 670 \u00b0C. Inquire now!","breadcrumb":{"@id":"https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/#primaryimage","url":"https:\/\/imetrologie.com\/wp-content\/uploads\/2023\/05\/AM1751_internet.png","contentUrl":"https:\/\/imetrologie.com\/wp-content\/uploads\/2023\/05\/AM1751_internet.png","width":1000,"height":666},{"@type":"BreadcrumbList","@id":"https:\/\/imetrologie.com\/en\/produkte\/temperature-measuring-systems\/sprt-resistance-thermometer\/am1751\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/imetrologie.com\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/imetrologie.com\/products\/?lang=en"},{"@type":"ListItem","position":3,"name":"Temperature Measuring Systems","item":"https:\/\/imetrologie.com\/en\/produkt-kategorie\/temperature-measuring-systems\/"},{"@type":"ListItem","position":4,"name":"SPRT \/ Resistance Thermometer","item":"https:\/\/imetrologie.com\/en\/produkt-kategorie\/temperature-measuring-systems\/sprt-resistance-thermometer\/"},{"@type":"ListItem","position":5,"name":"AM1751"}]},{"@type":"WebSite","@id":"https:\/\/imetrologie.com\/en\/#website","url":"https:\/\/imetrologie.com\/en\/","name":"Imetrologie","description":"Institut f\u00fcr Metrologie und Prozesstechnologie","publisher":{"@id":"https:\/\/imetrologie.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/imetrologie.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/imetrologie.com\/en\/#organization","name":"imetrologie GmbH Institut f\u00fcr Metrologie und Prozesstechnologie","url":"https:\/\/imetrologie.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/imetrologie.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/imetrologie.com\/wp-content\/uploads\/2022\/02\/Imetrologie-Logo-RGB-kl.jpg","contentUrl":"https:\/\/imetrologie.com\/wp-content\/uploads\/2022\/02\/Imetrologie-Logo-RGB-kl.jpg","width":595,"height":156,"caption":"imetrologie GmbH Institut f\u00fcr Metrologie und Prozesstechnologie"},"image":{"@id":"https:\/\/imetrologie.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/de.linkedin.com\/company\/imetrologie"]}]}},"_links":{"self":[{"href":"https:\/\/imetrologie.com\/en\/wp-json\/wp\/v2\/product\/10231","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/imetrologie.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/imetrologie.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/imetrologie.com\/en\/wp-json\/wp\/v2\/media\/7315"}],"wp:attachment":[{"href":"https:\/\/imetrologie.com\/en\/wp-json\/wp\/v2\/media?parent=10231"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/imetrologie.com\/en\/wp-json\/wp\/v2\/product_brand?post=10231"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/imetrologie.com\/en\/wp-json\/wp\/v2\/product_cat?post=10231"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/imetrologie.com\/en\/wp-json\/wp\/v2\/product_tag?post=10231"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}